EasyManua.ls Logo

Tokheim Quantium 310 - Changing the MP-T1 Pulser

Tokheim Quantium 310
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Ref 941113-001 Rev 2 Page 5-5
Quantium 310 Maintenance Manual Maintenance Procedures - Electronics
5.4 Changing the MP-T1 Pulser
Before starting the maintenance procedure, please refer to section 2.
Identify the relevant side of the dispenser with the pulser to be replaced (see section 2.3
for the identification of the dispenser sides).
Tools required
Replacement pulser including cable (refer to the Parts Manual for exact part identification)
Replacement Weights & Measurements seals
Small flathead screwdriver
3mm allen key
Wirecutters
Description of Parts
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the hydraulic area.
2) Locate the pulser to be replaced and break the seal using
wirecutters. Identify the pulser cable.
Note : the pulser cable has identification tags at each end.
3) Identify the relevant side panel to be removed and follow the
instructions given in section 2.6 to gain access to the cable glands.
4) Follow the instructions given in section 2.5 to gain access to the
calculator head.
5) Trace the cable up the relevant side of the dispenser to the
calculator head. Cut the cable ties using wirecutters and loosen
the relevant gland.
4 HEX CAP
SCREWS
PULSER
METER
PULSER CABLE

Table of Contents

Related product manuals