Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-24 Document Ref 941113-001 Rev 2
INSTRUCTIONS
1) Follow the instructions given in section 2.4 to gain access to the hydraulic area.
2) Follow instructions in section 4.10.1 to remove the motor
relay from the centrifugal switch cover.
3) Disconnect the furthest left spade from the terminal rail.
4) Use a magnetic cross head screwdriver to loosen and
remove the two screws on the terminal rail. Move the
terminal rail clear of the centrifugal switch cover.
5) Use the magnetic cross head screwdriver to loosen and
remove the remaining two screws on the black plastic
centrifugal switch cover.
4.10.2 MOTOR CENTRIFUGAL SWITCH
(SINGLE PHASE MOTORS ONLY)
Before starting the maintenance procedure, please refer to section 2.
The centrifugal switch is accessed from side B of the dispenser (see section 2.3
for the identification of the dispenser sides).
Tools required
Various sized allen keys
Small magnetic cross head screwdriver
Cross head screwdriver
Description of Parts
MOTOR
RELAY
CENTRIFUGAL
SWITCH COVER
CENTRIFUGAL SWITCH
ACTUATOR
SHAFT

Table of Contents