Document Ref 941113-001 Rev 2 Page 4-25
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
6) Carefully remove the switch cover completely and
place in a safe position.
7) Use a small allen key to loosen the grub screw on the
rotating section of the centrifugal switch. Remove the
rotating section completely and place in a safe position.
8) Use an alley key to loosen the two screws on the
centrifugal switch.
9) Remove the two screws, centrifugal switch and black
plastic block.
10) Disconnect the terminals from the centrifugal switch and
re-connect to the replacement centrifugal switch.
11) Re-fit the two screws and black plastic block to the new
centrifugal switch and secure to the motor.
IMPORTANT : Position the centrifugal switch so that
the inner actuator finger is as far away from the shaft
as possible.