Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-26 Document Ref 941113-001 Rev 2
12) Re-fit the rotating section to the centrifugal switch and secure to the motor by
tightening the grub screw.
13) Re-fit the centrifugal switch cover and secure in position by tightening the two
short screws.
Note: Use the shorter screws for the centrifugal switch cover and the longer
screws for the terminal rail.
14) Re-fit the two screws onto the terminal rail and secure to the motor.
15) Re-connect the furthest left spade to the terminal rail.
IMPORTANT: This connector must be re-connected.
16) Re-fit the motor relay and secure in position by tightening the top and bottom
mounting screws.
17) Re-fit the rear cover and use the allen key to refit the four hex head screws to
secure in position.
WARNING: ENSURE ALL RELAY WIRES ARE
CLEAR PRIOR TO RE-FITTING THE REAR
COVER. IF REQUIRED, PUSH THE WIRES
BACK INTO THE MOTOR.
18) Ensure that all tools and unused materials are
removed.
19) Secure the hydraulic door to the dispenser and lock.
20) Re-instate power to the dispenser.
21) Dispose of all waste accordingly.