EasyManua.ls Logo

Tokheim Quantium 310 - Page 51

Tokheim Quantium 310
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Ref 941113-001 Rev 2 Page 4-23
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
4) Locate the rear cover of the motor. Use an allen key to
loosen and remove the four hex head screws on the rear
cover.
5) Remove the rear cover completely and place in a safe
position.
6) Use a magnetic cross head screwdriver to loosen and
remove the top mounting screw above the motor relay.
7) Use a cross head screwdriver to loosen the bottom
mounting screw below the motor relay.
Note: Do not remove this screw.
8) Remove the connectors from the motor relay and re-fit
to the new relay.
9) Position the new motor relay, re-fit the top mounting
screw and tighten the bottom mounting screws to secure
in position.
10) Re-fit the rear cover and use the allen key to tighten the four hex head screws to
secure in position.
WARNING: ENSURE THE RELAY WIRES
ARE CLEAR PRIOR TO RE-FITTING THE
REAR COVER. IF REQUIRED, PUSH THE
WIRES BACK INTO THE MOTOR.
11) Ensure that all tools and unused materials are
removed.
12) Secure the hydraulic door to the dispenser and lock.
13) Re-instate power to the dispenser.
14) Dispose of all waste accordingly.

Table of Contents