Document Ref 941113-001 Rev 2 Page 4-7
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
4) Carefully remove the bypass valve assembly (spring, damper,
valve) from the housing.
5) Fit new bypass valve assembly (spring, damper, valve) into the housing.
6) Re-fit the bypass valve cover using a new o-ring.
7) Re-instate power to the dispenser.
8) Using the flathead screwdriver, adjust the bypass valve as required. Re commended
pressure 2 to 2.5 bar (80 litres/minute flow rate) or 2.4 to 3 bar (130 litres/minute flow
rate).
9) Ensure that all tools and unused materials are removed.
10) Secure the hydraulic door to the dispenser and lock.
11) Dispose of all waste accordingly.