Document Ref 941113-001 Rev 2 Page 4-3
Quantium 310 Maintenance Manual Maintenance Procedures - Hydraulic
4) Carefully prise off the filter box lid and o-ring and
remove completely.
Note : there may be a release of pressure during this
procedure.
5) Remove the filter spring plate below the filter box lid.
6) Remove the filter from inside the filter box. Drain
excess fuel into a suitable container.
WARNING : BEWARE OF FUEL SPILLAGE.
7) Fit the new filter.
8) Re-fit the filter spring plate.
9) Re-fit the filter box lid using a new o-ring. Use the torque wrench to tighten the four nuts
to 5Nm.
10) Ensure that all tools and unused materials are removed.
11) Secure the hydraulic door to the dispenser and lock.
12) Re-instate power to the dispenser.
13) Dispose of all waste accordingly.