INSTRUCTIONS
1) Rigid Mast only : Using a 36mm spanner, disconnect the hose
from the connection on the rigid mast. Drain excess fuel into a
suitable container.
WARNING : BEWARE OF FUEL SPILLAGE.
Spring Mast only : Using a 36mm spanner, disconnect the hose
from the connection at the top of the dispenser. Drain excess
fuel into a suitable container.
WARNING : BEWARE OF FUEL SPILLAGE.
2) Spring Mast only : Using a 4mm allen key, disconnect the
hose clamp to release the hose.
3) Follow the instructions given in section 3.1 to remove the
nozzle.
WARNING : BEWARE OF FUEL SPILLAGE.
4) Rigid Mast only : Connect the new hose to the rigid mast.
Spring Mast only : Connect the new hose to the top of the
dispenser.
5) Spring Mast only : Re-connect the hose clamp to the new hose.
6) Re-connect the nozzle to the end of the new hose.
7) Ensure all tools and unused materials are removed.
8) Re-instate power to the dispenser.
9) Test for any leakages.
10) Dispose of all waste accordingly.