Maintenance Procedures - Hydraulic Quantium 310 Maintenance Manual
Page 4-16 Document Ref 941113-001 Rev 2
Using a 13mm spanner, loosen the two screws on the flange on the
flexible connection at the back of the EPZ pump.
Disconnect the flange and flexible connection from the EPZ pump
and move clear of the pump.
WARNING : BEWARE OF FUEL SPILLAGE.
5) Using a 10mm spanner, loosen and remove the two screws
on the meter connection at the top of the pump to disconnect
the fuel outlet pipe.
WARNING : BEWARE OF FUEL SPILLAGE.
6) If vent pipes are fitted as an option, use a 22mm spanner to disconnect
the bolts on the pump unit and driptray. Remove the vent pipe
completely.
NOTE : Adjacent motor(s) will need to be lowered into the
driptray in order to access the screws fixing the pump to pump
support bracket.
7) Follow the instructions given in section 4.5 to remove the v-belt.
8) Carefully lift motor (and bracket) out of the slots in the pump support
bracket and lower into driptray taking care not to damage the motor
cables.
9) Using a 13mm spanner, loosen and remove the four screws
on the pump support bracket below the pump. Carefully
remove the four isolation pads and retain for re-fitting.
10) EPZ PUMPS WITH EXTERNAL FILTER BOX ONLY
From side B of the dispenser, slide the pump and filter box
out towards the filter box end.
Remove the pump unit completely.
Note : Ensure the motor cabling is clear of the filter box.
WARNING : BEWARE OF FUEL SPILLAGE.