Maintenance Procedures - Electronics Quantium 310 Maintenance Manual
Page 5-18 Document Ref 941113-001 Rev 2
3) REPLACE IEB:-
•Remove the Comms Board as described.
•Locate the IEB on the WWC centre plate on side A of the
dispenser.
•Locate the connectors on the IEB. Disconnect ALL connectors
on the board by squeezing the clips and carefully pulling the
connector to release.
Note: Take care to note the position of the connector(s) on
the IEB.
•Use a flathead screwdriver to carefully prise off the two plastic
rivets on the IEB.
•Carefully remove the IEB.
•Position new IEB onto the WWC Centre plate and use the long
nose pliers to re-fit the two plastic rivets to secure.
•Replace Comms Board as described.
4) Ensure that all tools and unused materials are removed.
5) Close the calculator head door and lock.
6) Re-instate power to the dispenser.
7) Test operation of the new board(s).
8) Dispose of all waste accordingly.