1-7
[Dark area] : Black circle area to be observed by the specula microscope
[Dark area analysis] : Analysis method to calculate values related to the dark area (D.A.Density,
etc.) by automatically extracting dark areas from the captured image
[L-count method] : Analysis method to calculate values such as CD (cell density) according to
the area and cell center entered by the physician
[MA/MS] : Manual Alignment / Manual Shot
[MAX] : Maximum area
The area of the largest cell in the analyzed endothelium tissues
[MIN] : Minimum area
The area of the smallest cell in the analyzed endothelium tissues
[NUM] : Number of cells
The number of analyzed endothelium tissues
[Quick mode] : Capture mode in which the image selection screen does not appear when
capturing is completed.
This mode is for users who do not wish to observe 16 images of
endothelium tissues.
[SD] : Standard deviation
Standard deviation of the area of analyzed endothelium tissues
[TOMEY Link] : System for electronic medical records that controls the examination data
obtained with our products
[Auto Alignment] : Function to automatically align the sight in up/down/right/left/focus
directions
[Auto Shot] : Function to automatically capture an image when the sight in the
up/down/right/left/focus directions is optimized
[Auto Analysis] : Analysis method to calculate values such as CD (cell density) by
automatically extracting trace lines of cells on the captured image
[Power-save] : This is a function to automatically turn off the monitor when the instrument
is not operated for a specified time. Touch the monitor to return to normal
status.
[Touch Alignment] : Function to move the measuring head by touching the screen. This is used
for rough alignment.
[Manual Alignment] : Manual alignment
[Manual Shot] : To capture images manually
[Rx only] : This symbol on the label of this device states "Caution: Federal law
restricts this device to sale by or on the order of a licensed healthcare
practitioner."