TH2523 Series Operation Manual Ver1.2
61
For example: WrtCmd(“COMParator: BEEper NG”)
Query syntax: COMP:BEEPer?
Return value NG indicates fail beeper.
GD indicates pass beeper.
OFF indicates the beeper function is off.
The [:CompMode] command sets the compare mode of the instrument. The
COMParator[:CompMode]? query returns the current compare mode.
Command syntax: COMParator:CompMode BIN
COMPare
BIN BIN mode
COMPare Compare mode
For example: WrtCmd(“COMParator:CompMode BIN”)
Query syntax: COMP:CompMode ?
Return valueBIN bin mode
COMP compare mode
The [:LOADBinno] is used to load the BIN number. This command is only valid in compare
mode. The COMParator[:LOADBinno]? query returns the current status of the loaded bin
number.
Command syntax: COMParator: LOADBinno BIN1
BIN9
BIN1~BIN9 is the loaded bin number. In compare mode, provide the compare condition.
For example: WrtCmd(“COMParator: LOADBinno BIN1”);load the setup condition of BIN1.
Query syntax: COMP:LOADBinno?
Return valueBIN1~BIN9 the loaded bin number
7.1.7 BINSETup Subsystem Commands
Binsetup Subsystem Commands are used to set the bin comparison and compare judgment
condition.