Shenzhen Topwisdom Technology Co., Ltd
46
1. Laser Type: there are common (CO2 glass tube), radio frequency, radio frequency (pre
combustion) three kinds. When the laser is a RF laser that does not need to be pre ignited,
select the RF type; if it is a RF laser that needs to be pre ignited, please select the RF (pre
ignited) type (at this time, the control card will always send a pulse signal of 1 US width
to the laser in standby mode, so that it can be pre ignited).
2. Frequency: according to the laser Manual, set the laser tube PWM waveform frequency.
Generally, 20000 for the CO2 tube and 5000 for the RF tube.
3. Laser Min: the minimum duty ratio of the PWM waveform. It is the minimum power
when the laser light is OFF.
4. Laser Max: the maximum duty ratio of the PWM waveform. It is the rated maximum
power of the laser. The range set: 0≦the min duty ratio ≦the max duty ratio ≦100. f
the maximum duty ratio is equal to the minimum duty ratio, the light intensity is not
adjustable.
5. PWM DIR: press "Select" to change the PWM DIR. If you found when you set power
bigger, the intensity of laser beam is stronger. Then you should press "select" to change
the PWM DIR.
6. X Compensation 1: power compensation of laser head 1. When the origin is in the upper
left corner, the compensation mode is positive electrode, and the laser power will slowly
increase as the X axis moves away from the origin. When compensated as negative
electrode, the laser power will slowly decrease as the X axis moves away from the origin.
7. X Compensation 1 (%): set the power intensity to be compensated for the laser head 1 to
move from the origin position to the X-direction maximum width.
8. Y Compensation: power compensation of Y-direction laser. When the compensation