6. Restart the computer, to ground the equipment and the computer.
7. Replace a computer.
5.4 The Reading and Writing of U Disk Question
1. Q: Click the U disk file, showing "U disk is empty or error".
A: U disk error.
First, check whether the U disk port is correct.
Second, format the U disk into one of the FAT 32 type;
Third, change to another type of U disk
2. Q: Click the U disk file, showing "U disk reading…please wait", and the indicator is
off.
A: Replace the U disk extension line.
5.5 Ineffective water protection and over-range issues
1. Click to start the job, and it displays "The Laser 1 protection is alarm"
Answer: Water protection is invalid.
(1) Check the laser output port to see if the WP and GND are connected to the laser water
cooling device interface correctly;
(2) The water cooling protection detection is turned off, and in the user parameters, set the
"Cooling Check" to close.
2. Display "Outrange, whether to continue?"
Answer: beyond the range.
(1) Set the Autolaser range parameters according to the worktable size, set the required
processing positioning method, and check whether the graphic size exceeds the maximum XY
stroke;
(2) The processing starting point is improper, press the positioning key again at the
appropriate position.