52-EN
3. The garage door can now be moved manually.
4. To operate the gate manually for a longer period of time, you can insert the
locking pin(II) into the carriage(III) in the bore provided for this purpose. To
restore normal operation, loosen the locking pin(II).
4.6 Connecting the garage door drive to electrical power and
controls
DANGER
Hazardous voltage
Fatal electric shock when touching live parts.
Pull out the main plug from the mains socket before you open the
cover of the drive head.
Do not connect any live leads. Only connect potential-free buttons
and potential-free relay outputs.
After connecting all cables, close the cover of the drive head.
WARNING
Danger by optical radiation!
Sight can be severely restricted for a short time by looking directly
at a LED. This can result in serious injuries.
Do not look directly at an LED.
To reach the connection terminals, open the service flap at the drive head.
Afterwards, loosen both screws of the cover and remove the cover.
Fig.7: Opening the drive head cover