4.9.4 Menu8: Door adjustments
NOTICE
After the setting was changed, the force learning cycle must be re-
peated.
1. Select menu item"8".
ð After approximately 2seconds, the display flashes and the set value
appears. The factory setting is"4". For optimal movement and to maintain
the forces, select the corresponding door type.
2. If desired, adjust the setting with the aid of the OPEN(B) and CLOSE(C) but-
tons.
Menu value Door type
0 Double swing gate
1 Non-swinging door, Canopy
2 Swing door, tilting door, normal
3 Swing door, tilting door, sensitive running
4 Universal setting (factory)
5 Sectional door with tension spring fitting (Topspeed)
6 Sectional door with torsion spring fitting (Topspeed)
7 Industrial door with standard fittings
8 Side section door (Topspeed)
9 Side section door with secondary closing edge
3. Press the programming button (PROG button)(D).
ð The display shows"9".