EasyManua.ls Logo

Tormatic B-1200 - Menu 8: Door adjustments

Tormatic B-1200
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN-61
4.9 Special settings
4.9.1 Opening the special settings menu
1. To open the menu for special settings, keep the programming button (PROG
button) (D) pressed in for approximately 3seconds.
ð The display shows"3".
2. Press the programming button (PROG button) (D) again.
ð The display shows"4".
3. Keep the programming button (PROG button) (D) pressed in again for ap-
proximately 3seconds.
ð The display shows"5".
4.9.2 Menu5 + Menu6: Force limits for opening and closing
WARNING
Crush hazard at the door!
If the force limits are set too high, there is a risk of personal injury.
The factory setting is "6" for opening and "4" for closing.
The force on the main closure side must not exceed 400 N /
750ms!
NOTICE
We recommend selecting the according door type in menu 8
before carrying out the force learning cycle.
1. Select menu item"5".
ð After approximately 2seconds, the display flashes and the set value for
the force limit for opening appears.
2. If desired, adjust the setting with the aid of the OPEN(B) and CLOSE(C) but-
tons.
3. Press the programming button (PROG button) (D). The display shows "6".
After approximately 2seconds, the display flashes and the set value for the
force limit for closure appears.
4. If desired, adjust the setting with the aid of the OPEN(B) and CLOSE(C) but-
tons.
5. Press the programming button (PROG button)(D).
ð The display shows"7".