EN-73
9 Check lists
9.1 Check list for door system
Confirm features at start-up with a check mark.
No. Equipment Present? Features to be tested Note
1.0 Garage door
1.1 Manual opening and closing Smooth running
1.2 Fastenings/ connections State/ seat
1.3 Pivots/ joints State/ lubrication
1.4 Track rollers/ track roller holders State/ lubrication
1.5 Seals/ sliding contact strips State/ seat
1.6 Door frame/ door guide Alignment/ fastening
1.7 Door leaf Alignment/ state
2.0 Weight
2.1 Springs State/ seat/ setting
2.1.1 Spring strips State
2.1.2 Spring break device State/ rating plate
2.1.3 Safety elements (spring
connector,…)
State/ seat
2.2 Wire cables State/ seat
2.2.1 Mounting State/ seat
2.2.2 Cable drum
2.3 Fall protection State
2.4 Concentricity of T-shaft State
3.0 Drive/ control
3.1 Drive/ rail/ bracket
3.2 Electrical cables/ connections
3.3 Emergency release Function/ state
3.4 Control devices, push
buttons/hand transmitters
Function/ state
3.5 Limit stop State/ position
4.0 Safeguarding of crush and shearing zones
4.1 Force limit Stops and reverses
4.2 Protection against lifting of
persons
Door leaf stops at 20kg
4.3 Site conditions Safely distances