Removal
1. Park the machine on a level surface and disengage the PTO. Stop the engine, wait for all moving parts to stop,
and remove key. Engage the parking brake.
2. Disconnect the battery.
3. Loosen the clamp securing the choke cable to the choke plate on the engine (Figure 32).
4. Remove the choke cable from the plate, noting the position of the cable in the plate.
5. Remove the control panel assembly from the right console.
6. On the bottom side of the control panel assembly, loosen the jam nut securing the choke lever in place.
Remove the nut from the choke cable.
7. Pull the choke cable assembly through the control panel assembly and out of the machine.
Figure 32

Table of Contents