Workman MDX--D Page 6 -- 39 Chassis
Removal (Fig. 29)
1. Raise front hood to gain access to brake master cyl-
inder.
2. Remove cotter pin from the clevis pin that connects
master cylinder to brake pedal.
IMPORTANT: To prevent contamination of t he brake
system, make sure to clean components before dis-
assembly.
3. Clean hydraulic brake line area of master cylinder to
prevent contamination. Remove both brake lines from
master cylinder. Cap ends of brake lines and position
them away from master cylinder.
4. Remove two (2) flange head nuts and cap screws
that secure master cylinder to pedal frame.
5. Remove master cylinder from machine.
Installation (Fig. 29)
1. Position master cylinder to pedal frame and secure
with two (2) cap screws and flange nuts.
2. Remove plugs from brake lines. Install brake lines to
master cylinder.
3. Connect master cylinder to brake pedal with clevis
pin and cotter pin.
4. Bleed brakes (see Bleed Brake System in this sec-
tion).
5. Lower and secure front hood.
CAUTION
After servicing brake system components, al-
ways check the brakes in a wide open, level area
that is free of other persons and obstructions.
6. Check brake operation.