e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC
2 - 56
1628-0 Process-
ing
Drum life correction switch-
ing of the drum reverse
rotation amount
ALL 4
<0-15>
M Drum life correction
switching of the drum
reverse rotation amount
1
1628-1 Process-
ing
Drum life correction switch-
ing of the normal drum
rotation amount after the
reverse rotation
ALL 9
<0-15>
M Drum life correction
switching of the normal
drum rotation amount
after the reverse rota-
tion
1
1913 Process-
ing
The function clear LED
blinks
PPC 1
<0-1>
SYS Blinks when the value is
different from the
present default value
after copying (until auto
clear or all clear.)
0: Invalid (Always off)
1: Valid
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
06/04