December 2005 © TOSHIBA TEC e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 57
2
<<PM management setting code>>
The following items are displayed or set by using sub-codes at PM management setting in the table
below.
<Sub-codes>
0: Present number of output pages
- Means the present number of output pages.
1: Recommended number of output pages for replacement
- Means the recommended number of output pages for replacement.
3: Present driving counts
- Means the present drive counts (1 count = 2 seconds).
4: Recommended driving counts to be replaced
- Means the recommended drive counts for replacement (1 count = 2 seconds).
6: Present output pages for control
- Means the present number of output pages for controlling.
7: Present driving counts for control
- Means the present drive counts for controlling (1 count = 2 seconds).
Notes:
Sub-code 3 is equivalent to sub-code 7.
When the value of sub-code 3 is changed, the value of sub-code 7 is also updated and vice
versa.
Sub-code 0 is equivalent to sub-code 6.
When the value of sub-code 0 is changed, the value of sub-code 6 is also updated and vice
versa.
When “0” is set at one of sub-codes 0, 3, 6 and 7, the rest of them are automatically updated
to “0”.
06/05