e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC
2 - 58
Items
PM management setting <Procedure 4>
*Indicated in 8 digits
Remarks
Upper Fuser roller bushing 361-0, 1, 3, 4, 6, 7 <Default values of code 361
(e-STUDIO 163/203)>
Sub-code 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Photoconductive drum 1150-0, 1, 3, 4, 6, 7 <Default values of code 1150
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Drum cleaning blade 1158-0, 1, 3, 4, 6, 7 <Default values of code 1158
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Drum separation finger 1172-0, 1, 3, 4, 6, 7 <Default values of code 1172
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Main charger grid 1174-0, 1, 3, 4, 6, 7 <Default values of code 1174
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Needle electrode 1182-0, 1, 3, 4, 6, 7 <Default values of code 1182
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Ozone filter 1198-0, 1, 3, 4, 6, 7 <Default values of code 1198
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Developer material 1200-0, 1, 3, 4, 6, 7 <Default values of code 1200
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Transfer charger wire 1214-0, 1, 3, 4, 6, 7 <Default values of code 1214
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Separation charger wire 1224-0, 1, 3, 4, 6, 7 <Default values of code 1224
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
Fuser roller 1246-0, 1, 3, 4, 6, 7 <Default values of code 1246
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
06/07