ADJUSTMENT
3 - 31
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. → Adjustment Mode
(2) Select the A4/LT drawer. Key in the pattern number and press the [FAX] button to output a "Patch
chart for gamma adjustment".
(3) Place the patch chart for adjustment printed in step (2) face down on the original glass.
Place the chart aligning its side with 2 black squares against the original scale.
(4) Key in a code and press the [START] button.
→ The scanner reads the chart automatically and performs automatic gamma adjustment calcu-
lation (approx.30 sec.).
(5) When the adjustment has finished normally, "ENTER" is shown. Press the [ENTER] button to
have the adjustment results reflected.
(To cancel the reflection of adjustment results, press the [CANCEL] button.)
In the case of an abnormal ending, "ADJUSTMENT ERROR" is shown.
Press the [CANCEL] button to clear the error display. When it is cleared, the control panel display
will return to the ready state. Then, check if the patch chart on the original glass is placed in the
wrong direction or if it is placed inclined on the original glass, and then repeat step (3) and after-
ward.
Pattern No. Pattern No.
Remark Paper type
4 Color/black integrated When performing code 05-1642
All paper types
200
Color/black integrated When performing code 05-1642-0
Plain paper
204
Color/black integrated When performing code 05-1642-2
Recycled paper
206
Color/black integrated When performing code 05-1642-3
Thick paper1
208
Color/black integrated When performing code 05-1642-4
Thick paper2
210
Color/black integrated When performing code 05-1642-5
Thick paper3
212
Color/black integrated When performing code 05-1642-6
Thick paper4
214
Color/black integrated When performing code 05-1642-7
Special paper 1
216
Color/black integrated When performing code 05-1644-8
Special paper 2