e-STUDIO2820C/2830C/3520C/3530C/4520C © 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 76
3.11 Adjustment of the Separation Plate Gap
Perform this adjustment when the following parts are replaced or disassembled.
Adjustment tool to use: Separation plate gap jig
Fig. 3-38
Notes:
Perform gap adjustment when the fuser unit is at a normal temperature.
Make sure that the pressure roller is released.
Be careful not to damage the fuser belt and jig (to protect the fuser belt, the jig is made from
ABS).
Separation plate Fuser belt Fuser roller
Frame of fuser unit Heat roller
Fuser belt
Separation plate
Fuser rollerHeat roller Frame
Separation plate gap jig
0.6 - 1.0 mm