3
© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2820C/2830C/3520C/3530C/4520C
ADJUSTMENT
3 - 75
<Procedure>
Note:
Perform the adjustment while the TBU releasing lever is being pressed down after the installation
of the TBU.
(1) Take off 1 ozone filter, 2 rear covers and the ozone exhausting duct.
(2) Loosen 3 screws shown in the figure. (Tension is applied by the spring.)
(3) Tighten the 3 screws loosened in step 2.
(4) Reinstall the parts taken off in step 1.