e-STUDIO2820C/2830C/3520C/3530C/4520C © 2008 TOSHIBA TEC CORPORATION All rights reserved
PREVENTIVE MAINTENANCE (PM)
5 - 16
5.5.6 Main charger
Fig. 5-16
* F1: Main charger case
Clean the main charger case with a cloth soaked in water and squeezed tightly, and then wipe
them with a dry cloth.
Items to check Cleaning
Lubri-
cation/
Coat-
ing
Replacement
Opera-
tion
check
Parts
list
<P-I>
(x 1,000
sheets)
(x 1,000 drive
counts)
F1 Main charger case B 40-1
F2 Needle electrode 56/70/70
(56/56/70)
170 O 40-6
F3 Contact point of terminals B 40-2
40-3
F4 Main charger grid 56/70/70
(56/56/70)
170 40-14
F5 Main charger cleaner 56/70/70
(56/56/70)
170 40-15
F4
F3
F3
F5
F1
F2