e-STUDIO2820C/2830C/3520C/3530C/4520C © 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 66
3.5.2 Beam level conversion setting
A beam level for smoothing process (divided into 4) in the fax function can be set. In this setting the size
of dots is adjusted.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in a sub-code and press the [START] button.
(4) Key in an adjustment value.
(To correct a value once keyed in, press the [CLEAR] button.)
(5) Press the [ENTER] or [INTERRUPT] button to store the value. → The equipment goes back to
the ready state.
(6) Take the POWER OFF.
<Confirmation>
Check the beam level conversion setting with the actual fax data received, if possible.
Code Item to be adjusted Remarks
678-0 Beam level 0/4 The smaller the value is, the smaller the beam width
becomes. Therefore, the smaller dot is reproduced accord-
ingly. Acceptable values: 0 to 255
(Default: Level 0/4: 0, Level 1/4: 63, Level 2/4: 127, Level 3/
4: 191, Level 4/4: 255)
678-1 Beam level 1/4
678-2 Beam level 2/4
678-3 Beam level 3/4
678-4 Beam level 4/4