PREVENTIVE MAINTENANCE (PM)
5 - 27
* M4: Fuser belt, M5: Heat roller, M6: Fuser roller
When any or all of fuser belt, heat roller and fuser roller is replaced or taken off from the fuser
unit, perform adjustment for the separation plate gap.
P.3-76 "3.11 Adjustment of the Separation Plate Gap"
* M8: Fuser belt front thermistor
Clean the thermistor with alcohol if the toner or dirt is sticking to it when the fuser belt is replaced.
Do not deform or damage the thermistor during the cleaning. Replace the thermistor with a new
one if it is damaged or deformed regardless of degree.
* M12: Fuser unit gear
Wipe off any old grease, and then apply 3 to 4 rice-sized grains of white grease (Molykote HP-
300) onto the gear teeth.
5.5.14 Exit unit
Fig. 5-27
* N2: Lower exit roller
Wipe off any old grease, and then apply 0.5 to 1 rice-sized grains of white grease (Molykote HP-
300) onto the inside of the roller and both end faces of the shaft hole.
Items to check Cleaning
Lubri-
cation/
Coat-
ing
Replacement
Opera-
tion
check
Parts
list
<P-I>
(x 1,000
sheets)
(x 1,000 drive
counts)
N1 Upper exit roller A 46-21
N2 Lower exit roller W2 46-30
N2
N1