8
© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2820C/2830C/3520C/3530C/4520C
FIRMWARE UPDATING
8 - 9
(5) Select the item with the digital keys.
“*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the
item.
(6) Press the [START] button.
Updating starts and the processing status is displayed on the LCD screen.
(7) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is com-
pleted properly.
Fig. 8-2
Notes:
• “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. “Failed” appears next to the failed item on the status display. Turn OFF the
power, and then check the following items. After confirming and clearing the problems, restart
updating from the beginning.
- Do the USB media meet the conditions to be used for updating?
- Is the data file written properly on the USB media?
- Are the USB media installed properly?
- Do the USB media and equipment operate properly?
Item Remarks
1. OS Update Updating OS data
2. HDD SYS Update Updating Master data and System data
3. Engine Main Firmware Update Updating Engine ROM
4. Scanner Firmware Update Updating Scanner ROM
Status display during update Status display when update is completed
OS Update.......................... FROM write OS Update.......................... Completed
HDD SYS Update ............... Copy file HDD SYS Update ............... Completed
Engine Firm Update........... Flash Update Engine Firm Update........... Completed
Scanner Firm Update ..........Flash Update Scanner Firm Update ..........Completed