November 2003 Ā© TOSHIBA TEC 2 - 153 e-STUDIO3511/4511
ERROR CODE AND SELF-DIA GNOSTIC MODE
<<Procedure to copy the total counter value (08-257)>>
1. Turn ON the power while [0] and [8] are pressed simultaneously.
2. Key in the code ā257ā and press the [START] button (the following is displayed).
Note:
Before performing the following operations, note the current counter values.
3. Key in the value ā1ā or ā2ā and press the [START] button.
The value entered is displayed on the left of the ā%ā, and the [ENTER] button is displayed.
Note:
The value can be erased by pressing the [CLEAR] button to change as long as the [START]
button is not pressed. (The value on the left of the ā%ā is reset to ā0ā by pressing the [CLEAR]
button.)
⢠Key in ā1ā to copy the value of the total
counter (LGC board) (A) onto the value of
the backup counter (SYS board) (B).
⢠Key in ā2ā to copy the value of the backup
counter (SYS board) (B) onto the value of
the total counter (LGC board) (A).
4. Press the [ENTER] button to complete
overwriting of the counter value.
Note:
The screen returns to the code entry screen
without copying (overwriting) the value when
the [CANCEL] button is pressed.
(A)
(B)
(A)
(B)
04/09