November 2003 Ā© TOSHIBA TEC 3 - 67 e-STUDIO3511/4511 ADJUSTMENT
3.12.8 Adjustment of RADF opening/closing switch
Adjust the bracket position so that the switch is turned ON when the height A becomes 40-45 mm
(within the empty weight falling limit).
Glass surface
A
Center
Fig. 3-1226