November 2003 Ā© TOSHIBA TEC 3 - 65 e-STUDIO3511/4511 ADJUSTMENT
3.12.7 Adjustment of reverse solenoid
When operating the reverse solenoid, adjust it if the position of the flapper lever is out of the following
dimension.
Gap between A of the front frame and the flapper lever ā€œCā€: 0.5 mm to 2.0 mm
Adjusting procedure
(1) Remove the screw on the left and take off
the plate spring.
(3) While the plunger of the reverse solenoid is
put in the position to be turned ON (by
pressing it in the direction of an arrow),
loosen the screw on the right to adjust the
reverse solenoid so that the gap (C)
between A of the front frame and the flapper
lever is 0.5 mm to 2.0 mm.
(2) Align B of the front frame with the edge of
the reverse solenoid, and temporarily fix the
reverse solenoid with the screw on the right.
C
A
B
Plate spring
Fig. 3-1222
Fig. 3-1223
Fig. 3-1224