November 2003 Ā© TOSHIBA TEC 5 - 141 e-STUDIO3511/4511 TROUBLESHOOTING
04/09
(12)Turn the power OFF.
(13)Turn the power ON.
(14)Set the dial type. [USER FUNCTIONS] → [ADMIN] → [FAX] → [INITIAL SETUP]
5.3.3 Replacing SLG board
<CAUTION IN REPLACING SLG BOARD>
When the SLG board has been replaced, ā€œData transfer of characteristic value of scanner / SYS board
→ SLG board (05-363)ā€ must be performed.
5.3.4 NVRAM replacing and clearing
<CAUTION IN REPLACING AND CLEARING NVRAM>
When NVRAM has been replaced or cleared (ā€System all clearing (08-669)ā€), the following adjustments
must be performed.
1. Perform ā€œData transfer of characteristic value of scanner / SLG board → SYS board (05-364)ā€.
2. Perform ā€œImage quality control initialization (05-396)ā€ ( Chapter 3.3), and then perform
ā€œAutomatic gamma adjustment (05-1642, 1000 and 1002)ā€ consecutively ( Chapters 3.5.1
and 3.6.1).