November 2003 Ā© TOSHIBA TEC 5 - 141 e-STUDIO3511/4511 TROUBLESHOOTING
04/09
(12)Turn the power OFF.
(13)Turn the power ON.
(14)Set the dial type. [USER FUNCTIONS] ā [ADMIN] ā [FAX] ā [INITIAL SETUP]
5.3.3 Replacing SLG board
<CAUTION IN REPLACING SLG BOARD>
When the SLG board has been replaced, āData transfer of characteristic value of scanner / SYS board
ā SLG board (05-363)ā must be performed.
5.3.4 NVRAM replacing and clearing
<CAUTION IN REPLACING AND CLEARING NVRAM>
When NVRAM has been replaced or cleared (āSystem all clearing (08-669)ā), the following adjustments
must be performed.
1. Perform āData transfer of characteristic value of scanner / SLG board ā SYS board (05-364)ā.
2. Perform āImage quality control initialization (05-396)ā ( Chapter 3.3), and then perform
āAutomatic gamma adjustment (05-1642, 1000 and 1002)ā consecutively ( Chapters 3.5.1
and 3.6.1).