e-STUDIO3511/4511 ADJUSTMENT 3 - 46 November 2003 Ā© TOSHIBA TEC
3.9 Adjustment of the Scanner Section
3.9.1 Carriages
(1) Installing carriage wires
When replacing the carriage wires, refer illustrations below:
Fig. 3-901
Adjustment of the carriage wire tension is not necessary since a certain tension is applied to the
carriage wires by the tension springs.
Note:
Make sure the tension applied to the wire is normal.
Wire pulley
Tension spring
Bracket for carriage-1
Carriage wire
Carriage-2
Idler pulley
Hook
Idler pulley
Carriage-2
Carriage wire
Bracket for carriage-1
Hook
Tension spring
Wire pulley
[Front side]
[Rear side]