3.12.3 Adjustment of skew
When an image skew occurs, adjust it according to the following steps, Step 1 → Step 2 → Step 3.
Note:
Perform this adjustment after confirming that the equipment has been adjusted properly.
Prior to this adjustment, of RADF position and height are needed to be adjusted.
Step 1
Case A: Adjust the aligning adjustment position to the rear side ā€œ-ā€ of the original ( Chapter 3.12.5).
Case B: Adjust the aligning adjustment position to the rear side ā€œ+ā€ of the original ( Chapter
3.12.5).
White arrow: feeding direction
Step 2
Case C: Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw counterclockwise.
Case D: Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw clockwise.
Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the hinge
position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
Paper
Original
Fixing screw
Adjustment screw
Hand screw
Front side
Paper
Original
Fig. 3-1216
Fig. 3-1217
Fig. 3-1218
RADF
04/05