e-STUDIO3511/4511 PREVENTIVE MAINTENANCE 4 - 20 November 2003 Ā© TOSHIBA TEC
Fig. 4-215
*k4. Transfer belt recovery blade
Clean the surface of transfer belt recovery blade with a cloth soaked in water and tightly squeezed,
and the wipe it with a dry cloth when replacing the transfer belt cleaning blade.
If the edge of recovery blade is damaged, replace the blade regardless of the number of output
pages.
Fig. 4-214
*k2. Area around image quality sensor
Clean the shutter of the image quality sensor and around it. Do not touch the sensor head inside
the shutter.
*k3. Transfer belt home position sensor
Clean each surface of transfer belt home position sensors (2 pcs.) with a dry cloth when replac-
ing the transfer belt.