e-STUDIO3511/4511 TROUBLESHOOTING 5 - 54 November 2003 Ā© TOSHIBA TEC
[F091] NVRAM abnormality on the SYS board
(1) Turn the power OFF and start up the Setting Mode (08).
(2) When the message ā€œNVRAM ERROR DOES IT INITIALIZE?ā€ is displayed on the LCD, press the
[INTERRUPT] or [INITIALIZE] button. (NVRAM is initialized.)
(3) Perform the panel calibration (08-692).
Note:
When the NVRAM is initialized, the scanner and image processing related adjustments are also
initialized. Readjust them after the NVRAM initialization.
(4) Turn the power OFF and then back ON. If the error is not recovered, replace the NVRAM on the
SYS board.
[F092] SRAM/NVRAM abnormality on the SYS board
(1) Turn the power OFF and start up the Setting Mode (08).
(2) When the message ā€œNVRAM/SRAM ERROR DOES IT INITIALIZE?ā€ is displayed on the LCD,
press the [INTERRUPT] or [INITIALIZE] button. (SRAM is cleared and NVRAM is initialized.)
(3) Perform the panel calibration (08-692).
Note:
When the NVRAM is initialized, the scanner and image processing related adjustments are also
initialized. Readjust them after the NVRAM initialization.
(4) Turn the power OFF and then back ON. If the error is not recovered, replace the NVRAM on the
SYS board.
[F350] SLG board abnormality
(1) Check if the conductor pattern on the SLG board is short circuited or open circuited.
(2) Replace the SLG board.