2.SETTING ITEMS (ADMIN)
IEEE 802.1X Authentication Setting 161
2 SETTING ITEMS (ADMIN)
2
Specify the following items as required and press [Next].
[EAP-USER NAME] — Press this button to enter the EAP-User name.
[PASSWORD] — Press this button to enter the authentication password.
[RETYPE PASSWORD] — Press this button to re-enter the authentication password.
When you press the above buttons, the on-screen keyboard is displayed. Enter a value using the keyboard and
digital keys, and press [OK] to set the entry.
3
Confirm the settings and press [APPLY NOW].
The “NETWORK INITIALIZING” message is displayed and this equipment starts initializing the network interface
card to apply the changes.
[CRL Verification] shows whether the certificate revocation list (CRL) is enabled or disabled. To use CRL, it is
necessary to upload the certificate revocation list to the equipment from the TopAccess - Security Service
menu. Changing the CRL verification option from [Enable] to [Disable] or vice versa is also performed from
TopAccess. For details, refer to the TopAccess Guide.
Error messages
The following error messages may be displayed on the touch panel.
Message Cause
[802.1X] Auth Server/Switch couldn’t be contacted y The RADIUS server service is stopped.
y Configuration for the RADIUS server is not correct.
y The IEEE 802.1X switch has problem.
[802.1X] Authentication failed y The username or password that the user entered is not
correct.
y The certificates uploaded are wrong.
[802.1X] Falling back to non-802.1X mode Network communication has begun using the fall back function,
ignoring IEEE 802.1X authentication.