e-STUDIO520/600/720/850 DRUM/CLEANER UNIT March 2005 © TOSHIBA TEC
11 - 14
(3) Disconnect 2 connectors, remove 3 screws
and take off the motor and solenoid with the
bracket.
Fig.11-27
(4) Remove 2 screws and take off the cleaning
brush drive motor.
(5) Remove 2 screws and take off the drum sep-
aration finger solenoid.
Fig.11-28
Bracket
Screw
Screw
Drum separation finger solenoid
Cleaning brush
drive motor