EasyManua.ls Logo

Toshiba E-STUDIO520 - Page 303

Toshiba E-STUDIO520
466 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 FUSER UNIT
14 - 13
7) Abnormality detection by the thermistors
The table below shows the judging conditions of abnormal temperatures of the fuser roller and the
pressure roller, and their checking timing.
Checking
timing
Condi-
tion
Temperature judged
Error
code
Counter
(08-400)
Error
judging
timing
Center
ther-
mistor
Rear
ther-
mistor
Front
ther-
mistor
Pres-
sure
roller
ther-
mistor
Power ON 1 240°C or
above
- - - C449 9 Power ON
- 250°C or
above
- -
- - 270°C or
above
-
- - - 250°C or
above
C468 8
2 40°C or
below
150°C or
above
- - C412 2
150°C or
above
40°C or
below
- -
Detecting
40°C
1 240°C or
above
- - - C449 19 On usual
- 250°C or
above
- -
- - 270°C or
above
-
- - - 250°C or
above
C468 18
2 40°C or
below
- - - C412
(C411)
2
(1)
Fixed time
- 40°C or
below
- -
Detecting
100°C
1 240°C or
above
- - - C449 19 On usual
- 250°C or
above
- -
- - 270°C or
above
-
- - - 250°C or
above
C468 18
2 100°C or
below
- - - C446
(C443)
3
(6)
Fixed time
- 100°C or
below
- -
When pre-
running end
temperature /
ready tem-
perature is
detected
1 240°C or
above
- - - C449 22 On usual
- 250°C or
above
- -
- - 270°C or
above
-

Table of Contents