152 GX9 ASD Installation and Operation Manual
Synchronized Torque Bias Input Selection
Program Torque Torque Control
This parameter Enables/Disables the Synchronized Torque Bias input
function. When enabled, this parameter identifies the source of the
Synchronized Torque Bias input signal.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F422
Parameter Type — Selection list
Factory Default Disabled
Changeable During Run — Yes
Tension Torque Bias Input Selection (Torque Control)
Program Torque Torque Control
This parameter Enables/Disables the Tension Torque Bias input function and
identifies the source of the Tension Torque Bias input signal when enabled.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F423
Parameter Type — Selection List
Factory Default Disabled
Changeable During Run — Yes
Load Sharing Gain Input Selection
Program Torque Torque Control
This parameter Enables/Disables the Load Sharing Gain input function and is
enabled by selecting a Load Sharing Gain input signal source.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F424
Parameter Type — Selection List
Factory Default Disabled
Changeable During Run — Yes
F422 F424