–37–
Installation Manual
■9. DN setting
Detailed data of various models of air conditioner can be set.
Be sure to stop operation of the air conditioners.
For details on codes and data to be set, refer to the Installation Manual and Service manual of the indoor unit and outdoor unit.
1 In the “Field setting menu” screen, press
[ ] and [ ] to select “DN setting”, and
then press [ Set/Fix]
2 Press [ ] and [ ] to select “Indoor unit”
or “Outdoor unit”, and the press [ Set/
Fix]
If “Indoor unit” was selected, the fans and louvres of
the indoor units operate.
When doing group connections:
The fans and louvres of the selected indoor units
operate.
3 Press [ ] to black highlight the code (DN),
and then press [ ] and [ ] to set the
code
4 Press [ ] to black highlight the data, and
then press [ ] and [ ] to set the data
5 After finishing setting the data of the code
(DN), press [ Set/Fix]
“Continue?” is displayed.
6 To set the data of other codes (DN), press
[Set/Fix]
To not do other settings, press [ Return]
The changes are fixed, and the “Field setting menu”
screen returns.
“ ” appears while data is changing.
When doing group connections:
Press [ Return] to open the unit selection screen.
In the unit selection screen, press [ Return] to
briefly display “ ”, and then return to the “Field
setting menu” screen.