2-22
Strata CTX I&M September 2002
Strata CTX100 Installation
♦
Do Not Run Cables Out the Top – Cabling from either cabinet should be routed out the lower
sides, not from the top of the cabinet(s) (see Figure 2-21).
Figure 2-21 Avoid Improper Cable Routing
2. Remove the left or right cover(s) of
the cabinet and knock out the
rectangle(s) to create a hole for the
cables, as needed (see Figure 2-22).
Note
Cables can be run out of either
side of Base or Expansion
cabinets.
3. Connect applicable wiring (e.g.,
modular Exchange line cords, 25-
pair amphenol connector cables) to
the front of the PCBs as described
earlier.
4. Secure all Amphenol cables to the
cabinets with tie wraps (see Figure
2-23).
6008
P ower S upplyP ower S upply
5968
R un c ables through cover
knoc k-outs holes
(on all side covers)
To avoid heat problems,
do not store items on
top of the c abinets.
Figure 2-22 Base and Expansion Cabinet Cables and
Connectors
Figure 2-23 Tie-wrap Cables