RT-SVP011E-EN 31
TD7 Display
Heating
Touch the Heating button to view Heating status information in the table below.
The data presented in this table is uni
t configuration dependent.
Outdoor Air Damper Position Discharge Pressure Ckt1 Discharge Saturated Temperature Ckt2
Economizing Discharge Saturated Temperature Ckt1 Suction Temperature Evap2B
Economizer Airside Enable Active Suction Temperature Evap1B Condenser Air Flow Ckt2
Economizer Decision Method Condenser Air Flow Ckt1 EXV Status Percent Evap2A XXX.X%
Econ Enable Min Outdoor Air Temp
Setpoint
EXV St
atus Percent Evap1A XXX.X% EXV Status Percent Evap2B
Outdoor Air Temperature Active EXV Status Percent Evap1B Condenser Fan Relay 1 Ckt2
Outdoor Air Humidity Active Condenser Fan Relay 1 Ckt1 Condenser Fan Relay 2 Ckt2
Outdoor Air Enthalpy Active Condenser Fan Relay 2 Ckt1 Condenser Fan Relay 3 Ckt2
Return Air Temperature Condenser Fan Relay 3 Ckt1
Condenser Fan VFD Run Command
Ckt2
Return Air Humidity
Condenser Fan VFD Run Command
Ckt1
Condens
er Fan VFD Percent Freq Cmd
Ckt2
Return Air Enthalpy
Condenser Fan VFD Percent Freq Cmd
Ckt1
Hot Gas
Bypass Valve Status Percent
Ckt2
Mixed Air Temperature EvapA
Hot Gas Bypass Valve Status Percent
Ckt1
Starts Cprs
r2A
Mixed Air Temperature EvapB Starts Cprsr1A Starts Cprsr2B
Mixed Air Temperature Estimated Starts Cprsr1B Starts Cprsr2C
Evap Leaving Air Temperature EvapA Starts Cprsr1C Running Time Cprsr2A
Evap Leaving Air Temperature EvapB Running Time Cprsr1A Running Time Cprsr2B
Evap Leaving Air Temperature
Estimated
Running Time Cprsr1B Running Time Cprsr2C
Occupied Standby Cooling Setpoint
Ac
tive
Running
Time Cprsr1C Cond Reheat Valve Pos Pct Ckt2
Dehumidification Control Status Cond Reheat Valve Pos Pct Ckt1 Cond Cooling Valve Pos Pct Ckt2
Discharge Air Cooling Setpoint Active Cond Cooling Valve Pos Pct Ckt1
Reheat Pumpout Relay Enable
Table 3. Cooling, Circuit 1 and Circuit 2 level status (continued)
Cooling Cooling - Circuit 1 Cooling - Circuit 2
Table 4. Heating status
Heating
Heating Capacity Primary Status
Space Temp Heating Setpoint Status
Discharge Air Temperature Active
Discharge Air Heating Setpoint Status
Space Temperature Active
Occupied Heating Setpoint Active
Unoccupied Heating Setpoint
Morning Warmup Setpoint
Daytime Warmup Setpoint