Programming Codes iTherm
®
280 Programmer’s Guide
28-04430 Rev K Page 145
Function Print the Electronic Journal
ASCII [ESC][GS]P< S
l
>< S
h
>< L
l
>< L
h
>
Hexadecimal 1BH 1DH 50H < S
l
>< S
h
>< L
l
>< L
h
>
Decimal <27> <29><80> < S
l
>< S
h
>< L
l
>< L
h
>
IPCL &%EP <S> <L> (L and S are 4 digits ie. 00100020 for 20 records starting
at 10)
EPOS
Description This command prints all or part of the electronic journal. <S
h
>*256 + <S
l
>
specifies the first record to be printed and <L
h
>*256 + <L
l
> specifies the
number of records to print. If <L
h
>*256 + <L
l
> are 0, records from the
specified start to the last record are printed. Setting both start and end to
0 will print the complete contents of the electronic journal.
Note: The first record is identified as record 1.
Function Report the Electronic Journal
ASCII [ESC][GS]R< S
l
>< S
h
>< L
l
>< L
h
>
Hexadecimal 1BH 1DH 52H < S
l
>< S
h
>< L
l
>< L
h
>
Decimal <27> <29><82> < S
l
>< S
h
>< L
l
>< L
h
>
IPCL &%EQ <S> <L> (L and S are 4 digits ie. 00100020 for 20 records starting
at 10)
EPOS
Description This command reports all or part of the electronic journal. <S
h
>*256 +
<S
l
> specifies the first record to be printed and <L
h
>*256 + <L
l
> specifies
the number of records to report. If <L
h
>*256 + <L
l
> are 0, all records from
the specified start to the end are reported. Setting both start and end to 0
will report the complete contents of the journal.
Note: The first record is identified as record 1.
The report format will be as follows: