EasyManua.ls Logo

TransAct Ithaca 280 - Table 53 Peripheral Device Bit Definitions

TransAct Ithaca 280
318 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Codes iTherm
®
280 Programmer’s Guide
28-04430 Rev K Page 225
Function Clear buffer(s)
ASCII [DLE] [DC4] <8> d1…d7
Hexadecimal 10H 14H <8> d1…d7
Decimal <16> <20> <8> d1…d7
Range d1=1, d2=3, d3=20, d4=1, d5=6, d6=2, d7=8
Description The [DLE] [DC4] <8> command clears all data stored in the receive buffer and
the print buffer.
Transmits the following three bytes of data
Hex
Decimal
Amount of data
Header
37H
55
1 byte
Flag
25H
37
1 byte
NUL
00H
0
1 byte
Enters in standard mode
Function Select Peripheral Device Status
ASCII [ESC] = <n>
Hexadecimal 1BH 3DH <n>
Decimal <27> <61> <n>
Range 1 n 3
Description The [ESC] = <n> command selects the device to which the host computer sends
data, based on the value of <n> listed below.
Bit
Off/On
Hex
Decimal
Function
0
Off
00H
<0>
Printer disabled
On
01H
<1>
Printer enabled
1
Off
00H
<0>
Customer display disabled
On
02H
<2>
Customer display enabled
2-7
-
-
-
Undefined
Table 53 Peripheral Device Bit Definitions
Note: Epson Customer display is not supported by the iTherm
®
280
printer.

Table of Contents