Table 37 MPRX Commands Listed Numerically
Number Command Name Reader Message
63 Reset reader
Model [model]
Ver [version no.]
SN [serial no.]
Copyright [date]
TransCore
6400 Turn o RF
#Done
6401 Turn on RF
#Done
641 Select RF-by-input control (default)
#Done
642NN Select RF operating frequency
#Done
643NN Set ATA operating range (distance)
#Done
6431F
ATA Operating Distance = Maximum
(default)
#Done
644NN Set RF attenuation
#Done
64400 RF Attenuation = Full Power (default)
#Done
645NN Set SeGo protocol operating range (distance)
#Done
6451F
SeGo protocol operating range distance =
Maximum (default)
#Done
647XXX
Select RF operating frequency from 860 to
930 in 250 kHz steps
#Done
65 Reset power fail bit
#Done
66F Load default operating parameters
#Done
6900
Disable presence without tag reports
(default)
#Done
6901 Enable presence without tag reports
#Done
6920 Turn RF o on timeout
#Done
6921 Turn RF o on timeout/tag
#Done
MPRX User Guide
TransCore Proprietary
D–122