Table 38 MPRX Commands Listed Alphabetically
Command Name Number Reader Message
Enable software flow control
(default)
6141
#Done
Enable tag translation mode 453
#Done
Get user-programmable group
select equals (GSE) filter data
549
The response data is formatted
similar to the data in the
configuration command.
Load default operating parameters 66F
#Done
MUX between RF ports 0 and 1 851
#Done
MUX between RF ports 0, 1, 2, and 3 853
#Done
MUX between RF ports 0, 1, and 2 852
#Done
MUX RF port 0 (default) 850
#Done
MUX test mode RF port 1 only 891
#Done
MUX test mode RF port 2 only 892
#Done
MUX test mode RF port 3 only 893
#Done
No time and date appended 300
#Done
Reader ID Number (default) 6000
#Done
Report buered handshakes 577
HDSH C0 <ww> C1 <xx> C2
<yy> C3 <zz>
Request sensor status change 552
MUX x<0 to 3> <MPRX>
Reset power fail bit 65
#Done
Reset reader 63
Model [model] Ver
[version no.] SN [serial
no.] Copyright [date]
TransCore
Reset uniqueness 440
#Done
RF Attenuation = Full Power
(default)
64400
#Done
SeGo protocol operating range
distance = Maximum (default)
6451F
#Done
Select 1 valid ID code (default) 4200
#Done
Select 2 valid ID codes 4201
#Done
 Appendix D Command Quick Reference
TransCore Proprietary
D–127

Table of Contents