457 Disable SeGo Protocol Tag Initialization During Multi-tag Sort
#457 disables the reader from sending the SeGo protocol tag initialize command as part
of the multi-tag sort function. Any SeGo protocol tags already identified by the reader
during the sort process will not be re-identified as long as they remain powered in the
RF field. The reader will only identify new tags that come into the RF field or tags that
do not remain powered in the RF field.
Reader response: #Done
480 Disable ATA
#480 disables the reader from reading ATA protocol tags.
481 Enable ATA
#481 enables the reader to read ATA protocol data from tags if the reader is programmed to
read this tag protocol.
484 Disable SeGo
#484 disables the reader from reading SeGo protocol data from tags.
485 Enable SeGo
#485 enables the reader to read SeGo protocol data from tags if the reader is programmed
to read this tag protocol.
488 Disable eATA
#488 disables the reader from reading factory-programmed eATA data from tags.
489 Enable eATA
#489 enables the reader to read factory-programmed eATA data from SeGo protocol tags.
Reader Status — Command Group 5
Group 5 commands provide status reports on the parameters and operation of the reader.
505 Display Software Version
#505 displays the reader model number, software version information, and assigned serial
number.
Reader response: Model E4 Series Ver X.XX SNSSSSSS
where
X.XX Version number
SSSSSS Serial number of the unit, skipping the fourth character printed on
the reader product
label
MPRX User Guide
TransCore Proprietary
5–66